42
Technical Data
AQUATOP T12C-T19C
Heat Pump Type AQUATOP T12C T14C T19C
Model Type Compact Heat Pumps
Standard Data Heat Pumps Brine
W35 W50 W35 W50 W35 W50
Heating capacity (Qh) B0 kW 12 11.3 14.4 13.5 18.5 17.3
Cooling capacity (Qo) B0 kW 9.2 7.6 11.1 9 14.5 11.9
El. power consumption 1) (Pe) B0 kW 2.8 3.8 3.3 4.5 4.0 5.5
Performance rating 1) (COP) B0 (-) 4.3 3.0 4.3 3.0 4.6 3.2
Standard Data Heat Pumps Water
Heating capacity (Qh) W10 kW 15.9 14.7 19.1 17.5 24.5 22.3
Cooling capacity (Qo) W10 kW 13.3 11.0 15.6 12.7 20.3 16.7
El. power consumption 1) (Pe) W10 kW 2.6 3.7 3.5 4.8 4.2 5.8
Performance rating 1) (COP) W10 (-) 6.0 4.0 5.5 3.7 5.8 3.9
Coolant R 407 c
Oil Ester oil
Oil charge l 1.36 1.85 1.89
Charge volume coolant kg 2.2 2.4 2.7
Geothermal heating system length
(50 W/m acc. to AWP)
DN 32 m 2 x 92 2 x 111 3 x 97
Evaporator, Brine Side
Water content WT l 2.0 2.1 2.4
Volume flow (3.0 K Δt with B0/W35) l/h 2928 3516 4625
Volume flow (3.0 K Δt with W10/W35) l/h 4233 4941 6475
Pressure loss (3.0 K Δt with B0/W35) kPa 15 14 21
Pressure loss (3.0 K Δt with W10/W35) kPa 31 28 41
Residual pressure with SO/W35 kPa 93 89 71,5
Residual pressure with W10/W35 kPa 65.5 61 28.5
Medium water/ethylene glycol % 75/25
Installed brine pump Top S 25/10 Top S 25/10 Top S 25/10
Condenser Heating Side
Water content WT l 2,4 2,9 2,9
Volume flow (10 K Δt) l/h 1476 1770 2272
Pressure loss (10 K Δt) kPa 9 10 12
Medium water % 100
Installed heat pump RS 25/6 RS 25/6 RS 25/7
Residual pressure 10 K Δt kPa 35 30 38
Usage Range
Heat source temperature min./max. °C -8 / +20 -8 / +20 -8 / +20
Heating flow temperature min./max. °C 20/55 20/55 20/55