
DS7060 Reference Guide Copyright © 1996-97 Detection Systems, Inc. Page 37
SIA Format
SIA reporting allows the installer to select the type of event each report
will send to the central station. For example, if a burglary zone is used as
a 24 hour panic zone, it can now report as a PA (Panic Alarm) when using
the SIA Format.
The event type is programmed in the extended digit of the report (ad-
dresses 24-36). To activate a report using the SIA Format, place a “1” (or
any digit other than 0) in the first reporting digit. To select the type of event
for this report, place one of the following values as the second (extended)
digit.
Komentáře k této Příručce