
4/98
Page 10 Copyright 1997-98 Detection Systems, Inc. DS7060-AUS Reference Guide
• Intrusion:
This is an output programmed to latch
with any Burg zone alarm, including invisible and
silent zones. It will remain latched until the system
is disarmed regardless of the restore setting for the
zone.
• On During Entry Pre-Alert:
This is an output
programmed to activate when a perimeter delayed
type zone is violated while the system is armed. It
will remain activated until the system is disarmed,
or until the entry delay time has expired.
• System Reset:
This is an output programmed to
activate only for 10 seconds after a PIN + [System
Reset] is entered at a keypad or if a fire zone with
verification activates. Output 1 turns on for 10
seconds, outputs 2 and 3 turn off for 10 seconds.
Outputs 2 and 3 are intended to be used to power
4-wire smoke detectors or any other device that
requires a power interruption to reset an alarm
condition.
• Armed:
This is an output programmed to activate
when the system is armed. It will remain activated
until the system is disarmed.
• Ground Start:
This is an output programmed to
activate for 3 seconds when the phone line is
seized. It is intended for use with ground start
phone systems that require a momentary short to
ground to obtain a dial tone. Connect a separate 12
VDC, DPDT relay. Connect both relay commons to
ground, and connect the N/O of each contact to
terminal positions 23 and 26 (one to terminal 23,
one to 26) of the DS7060. Connect one side of the
relay coil to the selected Programmable Output and
the other side of the coil to 12 volts (Terminal 5) (if
PO1 or PO2 is used), or to any Panel Common
terminal if PO3 is used. Not intended for UL Listed
systems. Not for use with phone line monitors.
• Ready to Arm (System Status):
This is an output
programmed to follow the “Status” light of the
keypad. It will activate when the system is ready to
arm with no zones violated.
• Follow Burg Alarm:
This is an output programmed
to activate when a zone is in an alarm condition. It
will remain activated until the system is disarmed or
the bell cutoff time expires. This output is intended
to activate bells and sirens. This will not activate
from Silent or Invisible zones.
• Follow Fire Alarm:
This is an output programmed
to activate when a zone is in an fire alarm condition.
It will remain activated until the system is disarmed
(or silenced using PIN + [Off] ) or the bell cutoff time
expires. This output is intended to activate bells and
sirens. This will not activate from Silent or Invisible
zones.
• Follow Burg and Fire Alarm:
This programs an
output to activate when any zone goes into alarm
condition.
• Follow Keypad Sounder:
This is an output
programmed to follow the keypad sounder. It
activates during the entry pre-alert . It does not
follow momentary keypad beeps such as
keystrokes.
• Duress:
This output activates when the duress
code is used to disarm the system.
Note:
If the Duress code is used to activate a
Programmable Output, entering any valid PIN +
[OFF} will deactivate the Programmable Output.
• Trouble:
This output activates when a trouble
condition is present.
• Off During Battery Test:
This output turns Off
(deactivates) for 2 seconds during a manual or
automatic battery test.
• Partial Armed:
This output activates whenever the
system is armed with one or more zones bypassed.
This includes manual bypasses, custom arming and
force arming.
• Follow Burg Alarm 20 Second Delay:
This output
will be delayed for 20 seconds after a zone enters
an alarm condition. It will remain activated until the
system is disarmed or the bell timeout expires.
Komentáře k této Příručce