4/98
DS7060-AUS Reference Guide Copyright 1997-98 Detection Systems, Inc. Page 3
(1&/2685(,167$//$7,21
The DS7060 control/communicator and the enclosure
are shipped together. The control, however, still needs
to be installed into the enclosure. Hardware for
mounting the enclosure to a wall, and the control to
the enclosure is located in its own hardware pack.
NOTE: This panel is intended for mounting in a
restricted access area and should be wall
mounted.
CAUTION: The control panel should only be
installed by authorized service
personnel.
• Use the enclosure as a template and mark the
mounting holes on the mounting surface.
• Pre-start the mounting screws for these holes.
Mount the enclosure.
• Knock out the desired wire entrances on the
enclosure.
CAUTION: The control is static sensitive. Make sure
you touch earth ground before handling
the control. This will discharge any static
electricity in your body.
EXAMPLE: Run the ground wire to the enclosure
before handling the control. Then,
holding the ground wire (or using a
ground strap), install the control.
• Insert the two support posts into the control retainer
holes as shown below in the Support Post
Assembly diagram.
• Slide the top of the control PCB into the two retainer
tabs.
• Once in the retainer tabs, the control will rest on the
two support posts.
• Secure the bottom of the enclosure by screwing the
bottom two holes through the support posts and
through to the control retainer holes.
CAUTION: Once the control is installed, be sure to
connect its ground wire to the top hinge
of the enclosure.